<- Back to digest

JSES - 2026-10-01 - Journal Article

Failure Patterns Leading to Revision After Distal Humerus Fracture Fixation: A Multicenter Study.

Elze M, Ellwein A, Bülow HJ, Hollinger B, Burkhart K, Schmalzl J, Nowotny J, Cucchi D, Mader K, Maier D, Voss A, Greiner S, Leschinger T, Hackl M

retrospective cohortLOE IIIn = 491 (411 in primary inferential analysis)Not reported as mean follow-up; time-to-revision reported (median: infectious 3.5 months, mechanical 6.0 months, functional 10.0 months).

Topics

shoulder elbowtrauma
PMID: 42822694DOI: 10.1016/j.jse.2026.09.012View on PubMed ->

Key Takeaway

Among 491 patients requiring revision after distal humerus fracture fixation, open fractures carried an OR of 5.88 for infectious failure, while implant malposition/secondary dislocation drove 43.1% of mechanical revisions.

Summary Depth

Choose how much analysis to show on this article page.

Summary

This multicenter retrospective study across 11 centers characterized mechanism-specific revision pathways in 491 adults who underwent revision after distal humerus fracture fixation, using multinomial logistic regression with mechanical complications as the reference. Mechanical failure (43.1%) and functional failure (41.4%) were nearly equally prevalent, with infectious failure in 15.6%; open fractures independently predicted infectious revision (OR 5.88, 95% CI 2.19–15.80), and younger age showed a statistically significant but clinically weak association with functional revision (OR 0.96 per year). Median time to revision stratified predictably by mechanism: 3.5, 6.0, and 10.0 months for infectious, mechanical, and functional pathways respectively.

Key Limitation

The study captures only patients who underwent revision, creating a selected failure cohort with no denominator of the total index fixation population, precluding calculation of true revision rates or identification of factors that prevent revision.

Original Abstract

BACKGROUND

Distal humerus fractures are associated with substantial complication and revision rates following operative fixation. Although overall complication frequencies are well documented, the specific mechanisms leading to revision surgery and their associated risk factors remain insufficiently characterized.

PURPOSE

To analyze mechanism-specific patterns and determinants of revision surgery after operative treatment of distal humerus fractures, focusing on infectious, mechanical, and functional failure pathways.

METHODS

This multicenter retrospective cohort study included 491 adult patients undergoing revision surgery after distal humerus fracture fixation across 11 specialized centers. The full cohort was used for descriptive characterization of all recorded revision causes, allowing overlapping complication categories. For the primary inferential analysis, 411 patients were included in a three-category outcome variable comprising infectious, mechanical, and functional leading revision pathways. Biological and degenerative complications were retained for descriptive characterization. Univariate and multivariable multinomial logistic regression analyses were performed to identify patient-, injury-, and treatment-related factors associated with specific revision mechanisms, using mechanical complications as the reference category. Time to revision was compared between groups.

RESULTS

Mechanical complications occurred in 177 patients (43.1%), functional complications in 170 (41.4%), and infectious complications in 64 (15.6%). In the complete descriptive cohort (n = 491), functional complications represented the most frequently recorded indication for revision surgery overall. The combined category of implant malposition/secondary implant dislocation accounted for the majority of mechanical failure mechanisms. Open fractures were independently associated with infectious complications (OR 5.88, 95% CI 2.19-15.80; p < 0.001). Revision surgery for functional impairment showed a statistically significant but weak association with younger patient age (OR 0.96 per year, 95% CI 0.94-0.98; p < 0.001), whereas fracture morphology and treatment-related variables were not independently associated with functional revision pathways after adjustment. Median time to revision differed significantly between groups, occurring earliest in infectious complications (3.5 months), followed by mechanical (6.0 months) and functional complications (10.0 months).

CONCLUSIONS

Revision surgery after distal humerus fracture fixation follows distinct mechanism-specific pathways rather than a uniform pattern of failure. Open fractures are strongly associated with infectious complications, whereas younger age showed only a weak association with functional revision pathways. Mechanical complications are predominantly characterized by implant malposition and secondary implant dislocation. These findings support a differentiated approach to postoperative surveillance, patient counselling, and mechanism-specific assessment.