Key Takeaway

Robotic-assisted THA achieved 97.2% survivorship free of revision at minimum 10-year follow-up with zero dislocations and 91.1% of cups within the Lewinnek safe zone.

Summary Depth

Choose how much analysis to show on this article page.

Summary

This study evaluated minimum 10-year clinical and radiographic outcomes of primary robotic-assisted THA in 215 hips with prospectively collected data. At final follow-up, mean Harris Hip Score was 93.0, HOOS-JR 89.1, and FJS-12 85.2, with six total revisions (2.8%): four for acute PJI (1.9%), one aseptic loosening (0.5%), and one leg-length discrepancy (0.5%). Notably, there were zero instability or dislocation events, and 91.1% of cups fell within the Lewinnek safe zone (40° ± 10° inclination, 15° ± 10° anteversion).

Key Limitation

Absence of a concurrent non-robotic control group makes it impossible to determine whether outcomes are attributable to robotic assistance, surgeon experience, patient selection, or secular trends in THA practice.

Original Abstract

BACKGROUND

Robotic-assisted total hip arthroplasty (rTHA) has been shown to assist with precision in component placement. However, limited evidence exists evaluating its effects on minimum 10-year clinical outcomes. The purpose of this study was to report the minimum 10-year clinical outcomes in a case series of patients who underwent rTHA.

METHODS

Prospectively collected data from patients who underwent primary rTHA between June 2011 and April 2015 were analyzed. Patients who had a complete minimum 10-year follow-up, including radiographs and validated patient-reported outcomes, were included. A total of 215 hips met the inclusion criteria. The patient-reported outcomes included the Harris Hip Score, Hip Disability and Osteoarthritis Outcome Score-Joint Replacement, Forgotten Joint Score-12 (FJS-12), visual analog scale pain, and patient satisfaction. Radiographic assessment included acetabular cup inclination, version, leg-length discrepancy, and cup placement relative to the Lewinnek and Callanan safe zones.

RESULTS

At the final follow-up, patients reported excellent outcomes, with mean Harris Hip Score 93.0 ± 12.6, Hip Disability and Osteoarthritis Outcome Score-Joint Replacement 89.1 ± 16.1, FJS-12 85.2 ± 22.4, visual analog scale pain 1.0 ± 1.9, and satisfaction 9.1 ± 1.8. The high FJS-12 score reflects that patients rarely or almost never thought about their hip in daily life. There were six revisions (2.8%): one for aseptic loosening (0.5%), one for leg-length discrepancy (0.5%), and four for acute postoperative infection (1.9%). Survivorship free of revision was 97.2% at 10 years. Radiographic analysis demonstrated that 91.1% of cups were within the Lewinnek safe zone and 87.4% within the Callanan safe zone. Notably, there were no cases of instability or dislocation.

CONCLUSIONS

Robotic-assisted primary THA was associated with a high degree of accuracy in component placement and durable clinical outcomes with high patient satisfaction and low revision rates at a minimum 10-year follow-up.

LEVEL OF EVIDENCE

Level IV.