<- Back to digest

JOA - 2026-10-07 - Journal Article

Clinical Outcomes of Rotating-Hinge Total Knee Arthroplasty in Primary and Revision Settings: A Retrospective Cohort Study.

Jabalameli M, Bagherifard A, Askari A, Sour B, Zareie B, Salehpour M

retrospective cohortLOE IIIn = 110 patients (120 knees); 52 primary, 68 revisionMean 118.0 months (primary); mean 72.0 months (revision)

Topics

arthroplasty
PMID: 42843681DOI: 10.1016/j.arth.2026.09.042View on PubMed ->

Key Takeaway

Rotating-hinge TKA achieved 5-year Kaplan-Meier survival of 98.1% in primary and 98.2% in revision settings, with no statistically significant difference between groups (log-rank P=0.58).

Summary Depth

Choose how much analysis to show on this article page.

Summary

This study asked whether rotating-hinge TKA outcomes differ between primary and revision indications by retrospectively analyzing 120 knees over a 12-year period using KSFS, OKS, and Kaplan-Meier survivorship. Both groups achieved clinically meaningful functional gains exceeding the OKS MCID of 5 points in 94.2% (primary) and 89.7% (revision) of cases. Five-year implant survival was statistically equivalent at 98.1% vs 98.2%, though only three total failures occurred across both cohorts.

Key Limitation

With only three failure events across 120 knees, the Kaplan-Meier analysis is underpowered to detect meaningful differences in survivorship between groups, and the wide confidence intervals (87.1–99.7% primary; 88.2–99.8% revision) reflect this imprecision.

Original Abstract

BACKGROUND

Rotating-hinge implants provide the highest constraint in total knee arthroplasty (TKA) and are used when stable alignment cannot be achieved with less constrained designs. Outcomes are difficult to interpret because primary and revision cases are frequently combined.

METHODS

We retrospectively reviewed 110 patients (120 knees) treated with rotating-hinge TKA from January 1, 2013, through June 30, 2025 (clinical follow-up updated through December 31, 2025), representing 120 of 4,893 (2.5%) of TKAs in this period. Cases were analyzed in two predefined groups: primary (52 knees) and revision (68 knees). There was no minimum follow-up threshold; all primary cases had at least 24 months. The mean follow-up was 118.0 months (range, 24.0 to 156.0) in the primary group and 72.0 months (range, 6.0 to 156.0) in the revision group. Function was assessed with the Knee Society Function Score (KSFS) and Oxford Knee Score (OKS). Implant survivorship (endpoint: any re-revision or component exchange/removal) was estimated by Kaplan-Meier analysis with log-rank comparisons.

RESULTS

Both groups improved significantly: KSFS change +35.1 ± 3.4 (primary) and +31.0 ± 6.2 (revision); OKS change +26.0 ± 8.6 and +24.7 ± 9.4, exceeding the 5-point OKS minimal clinically important difference in 94.2 and 89.7%, respectively. Intraoperative fractures occurred in five primary (9.6%) and four revision (5.9%) knees; deep infection occurred in one primary knee (1.9%). There were three knees that met the failure definition: one of 52 primary knees (deep infection, nine months) and two of 68 revision knees (aseptic loosening, 46 and 74 months). The Kaplan-Meier 5-year survival was 98.1% (95% confidence interval [CI], 87.1 to 99.7) in primary knees and 98.2% (95% CI, 88.2 to 99.8) in revision knees; log-rank P = 0.58.

CONCLUSION

Rotating-hinge TKA produced meaningful functional and patient-reported gains in both settings. Complications should be interpreted in the context of severe deformity, instability, bone loss, and revision complexity; attribution to underlying pathology, rather than implant constraint, remains inferential, as no matched comparator was available. These findings support selective use of modern rotating-hinge implants in high-complexity knees.