An Algorithmic Approach to the Diagnosis and Staging of Scapholunate Instability in Distal Radius Fractures Using 7 Fluoroscopic Parameters Shows High Reliability and Accuracy.

Waitayawinyu T, Sopasilapa P, Pinitchanon P, Boonyasirikool C

prospective cohortLOE IIn = 88N/A

Topics

hand
PMID: 42861864DOI: 10.1002/arj.70599View on PubMed ->

Key Takeaway

A 7-parameter intraoperative fluoroscopic algorithm stages scapholunate instability in distal radius fractures with ICC >0.89 and AUC up to 1.00, using arthroscopy as the reference standard in 88 wrists.

Summary Depth

Choose how much analysis to show on this article page.

Summary

This study evaluated whether seven intraoperative fluoroscopic parameters could reliably diagnose and stage SL instability concurrent with distal radius fracture fixation, using wrist arthroscopy (Geissler and EWAS classifications) as the reference standard in 88 consecutive wrists. All seven parameters demonstrated ICC >0.89 for intra- and interobserver reliability. The resulting staging algorithm achieved AUC 0.71–1.00 across instability grades, with specific cutoffs: SL angle <60° or delta-SL angle ≤4° plus delta-SR angle >11° identified no instability, while SL gap ≥2.5 mm or SL translation ≥2.4 mm identified advanced GIV/EIV-V instability.

Key Limitation

The single-center design with 88 wrists means the specific numeric cutoff values (e.g., SL angle 60° and 74°, delta-SR angle 11°) require external validation before adoption as universal thresholds.

Original Abstract

PURPOSE

To determine the reliability and diagnostic accuracy of fluoroscopic parameters for diagnosis and staging of scapholunate (SL) instability in distal radius fractures.

METHODS

Between May 2021 and March 2024, intraoperative fluoroscopic assessments were performed after fixation of unstable distal radius fractures. Imaging included anteroposterior, clenched-fist anteroposterior-ulnar deviation, true lateral, and modified scaphoid shift views. Wrist arthroscopy served as the reference standard, with staging according to Geissler (GI-GIV) and European Wrist Arthroscopy Society (EI-EV) classifications. Fluoroscopic parameters-SL gap, SL-ulnar deviation gap, SL translation, scaphoradius (SR) translation, SL angle, delta-SL angle, and delta-SR angle-were analyzed for intra- and interobserver reliability and diagnostic accuracy.

RESULTS

Eighty-eight wrists (38 men, 50 women) were included. Fluoroscopic parameters differed significantly across SL instability stages. A staging algorithm was developed using parameters with high intra- and interobserver reliability (intraclass correlation coefficient > 0.89) and good diagnostic accuracy (area under the receiver-operating characteristic [AUC], 0.71-1.00). The SL angle differentiated G0-II, GIII, and GIV instability, with cutoff values of 60° (AUC 0.74) and 74° (AUC 0.97). An SL angle < 60° or delta-SL angle ≤ 4°, combined with delta-SR angle > 11° (AUC 0.71), indicated non-SL instability (G0/E0), whereas delta-SR angle ≤ 11° indicated GI-II/EI-II instability. A delta-SL angle > 4° differentiated EIIIA from G0-II/E0-II (AUC 0.82) and EIIIB-C (AUC 0.88). Delta-SR angle ≤ 5° differentiated EIIIB-C from EIIIA (AUC 1.00). SL-ulnar deviation gap ≥ 2.9 mm, SL translation ≥ 1.8 mm, or SR translation ≥ 2.5 mm differentiated EIIIC from EIIIB (AUC 0.89-1.00). Advanced instability (GIV/EIV/V) was indicated by SL gap ≥ 2.5 mm, SL-ulnar deviation gap ≥ 3.2 mm, or SL translation ≥ 2.4 mm (AUC 0.86-0.95).

CONCLUSIONS

Fluoroscopic parameters identified in this study show high reliability and good diagnostic accuracy for diagnosis and staging of SL instability in distal radius fractures.

LEVEL OF EVIDENCE

Level II, diagnostic study of consecutive patients.