KSSTA - 2026-10-19 - Journal Article
Posterolateral corner deficiency amplifies varus-related anterior cruciate ligament forces under dynamic loading: A biomechanical study.
Gellhaus F, Deichsel A, Stening J, Albert A, Peez C, Behrendt P, Seekamp A, Raschke MJ, Horst K, Kittl C
Topics
Key Takeaway
PLC transection amplifies ACL forces by 91% at 8° varus and 40° flexion (80.0 N to 153.2 N), while Arciero PLC reconstruction eliminates varus- and flexion-dependent ACL force increases entirely.
Summary Depth
Choose how much analysis to show on this article page.
Summary
This cadaveric study quantified ACL forces across four varus alignments (0°–8°) and five flexion angles (0°–40°) under 200 N axial load in three PLC states: native, transected, and Arciero-reconstructed. In PLC-intact knees, only 8° varus produced significant ACL force increases (at 30° and 40° flexion); PLC transection lowered the threshold to 5° varus from 10° flexion onward, peaking at 153.2 ± 58.4 N versus 80.0 ± 12.3 N at neutral. PLC reconstruction normalized ACL forces with no significant effect of varus or flexion angle (p > 0.05).
Key Limitation
The small sample (n=8) and static axial loading protocol without muscle force simulation do not replicate the dynamic quadriceps and hamstring co-contraction forces present during in vivo varus-thrust loading, limiting direct clinical translation.
Original Abstract
PURPOSE
This study examined the influence of varus alignment, posterolateral corner (PLC) insufficiency, and PLC reconstruction on forces acting on the anterior cruciate ligament (ACL). It was hypothesized that increasing varus would increase ACL force, PLC transection would amplify this increase, and reconstruction would restore force toward PLC-intact values.
METHODS
Eight cadaveric knees (mean age 62 ± 12 years) underwent dynamic testing at 0°, 10°, 20°, 30° and 40° flexion under 200 N axial load in a materials testing machine with a custom five-degree-of-freedom setup. The ACL was tibially detached and refixated with 80 N using a custom tensioner. Lateral opening-wedge distal femoral osteotomy with external fixation and three-dimensionally printed wedges established 0°, 3°, 5° and 8° varus. Three conditions were tested: (1) native, (2) PLC transection (lateral collateral ligament and popliteus tendon) and (3) PLC reconstruction in Arciero technique.
RESULTS
Axial loading caused ACL forces in PLC-intact knees ranging from 77.1 ± 7.3 N (neutral alignment in 20° flexion) to 109.9 ± 46.8 N (8° varus at 40° flexion). Significant increases in ACL forces were observed at 30° (p = 0.006) and 40° (p = 0.001) of flexion with 8° varus. Following PLC transection, significant increases in ACL forces occurred at 5° varus and higher from 10° of flexion onwards, with a notable increase from 80.0 ± 12.3 (neutral) to 153.2 ± 58.4 N (8° varus, 40° flexion, p < 0.001). After PLC reconstruction, no significant effects of varus alignment or flexion on ACL forces were observed (p > 0.05).
CONCLUSION
Under axial compression and simulated varus-thrust loading conditions, varus alignment of 5° or less did not significantly increase ACL forces in PLC-intact knees, whereas 8° varus resulted in significantly increased ACL loading at selected flexion angles. PLC deficiency was associated with greater increases in ACL force with increasing varus alignment.
LEVEL OF EVIDENCE
NA.