<- Back to digest

Acta Orthopaedica - 2026-10-26 - Journal Article

Stable 2-year migration on radiostereometric analysis and improved gait speed and function after bicruciate-retaining TKA: a prospective cohort of 25 patients.

Mills K, Van Laarhoven SN, Defoort KC, Susan S, Heesterbeek PJC

prospective cohortLOE IVn = 25Mean 2 years (multiple time points assessed).

Topics

arthroplasty
PMID: 42928574DOI: 10.2340/17453674.2026.46950View on PubMed ->

Key Takeaway

BCR TKA demonstrated stable 2-year fixation with tibial total translation of 0.22 mm and femoral total translation of 0.43 mm, both below established RSA benchmark thresholds for aseptic loosening risk.

Summary Depth

Choose how much analysis to show on this article page.

Summary

This prospective RSA study evaluated tibial and femoral component migration and functional outcomes in 25 BCR TKA patients through 2 years. Tibial total translation was 0.22 mm and femoral 0.43 mm; tibial total rotation was 0.53° and femoral 0.64°, all below published benchmark thresholds predictive of late aseptic loosening. PROMs exceeded MCID thresholds, but gait speed improvement, while statistically significant, did not reach MCID and was comparable to healthy controls at 1 year.

Key Limitation

The absence of a concurrent control group (CR or PS TKA) makes it impossible to determine whether BCR TKA migration, functional recovery, or adverse event rates differ meaningfully from standard designs.

Original Abstract

BACKGROUND AND PURPOSE

In bicruciate-retaining total knee arthroplasty (BCR TKA) the preservation of both cruciate ligaments necessitates a different tibial tray design with reduced bone-implant interface. These ligaments also influence knee joint force dynamics and may thereby affect component migration. The primary aim of our study was to assess the fixation of BCR TKA up to 2 years postoperatively. Secondary aims included the evaluation of clinical and functional outcomes.

METHODS

This prospective study (https://osf.io/zqt8d) included 25 BCR TKA patients. Migration of both components was assessed at different follow-up time points by model-based radiostereometric analysis (RSA) using bone markers. Primary outcome was total translation (TT) and total rotation (TR) at the 2-year follow-up. Secondary outcomes included at-home gait parameters (gait speed, stride length, stride time) assessed with wearable sensors, patient-reported outcome measures (PROMs), and adverse events (AEs).

RESULTS

At the 2-year follow-up, least-squares mean tibial TT was 0.22 mm (95% confidence interval [CI] 0.16-0.28) (tibia) and femoral TT 0.43 mm (CI 0.30-0.57). The least-squares mean tibial TR was 0.53° (CI 0.43-0.63) and femoral TR 0.64° (CI 0.46-0.82). PROMs improved significantly after surgery, with improvements exceeding the predefined minimal clinically important difference (MCID). Gait outcomes revealed a significant gait speed improvement, which remained below MCID, and no significant difference from healthy controls 1 year postoperatively. AEs included 2 intraoperative tibial eminence fractures, 4 cases of persistent postoperative pain, and 2 cases of postoperative oedema with temporary knee stiffness.

CONCLUSION

RSA analysis of this BCR TKA demonstrated a stabilizing migration pattern that remained below established TKA benchmark values (for different designs), indicating good fixation at 2-year follow-up. The findings were accompanied by an improved PROM, whereas gait speed improvement was below MCID.