<- Back to digest

JAAOS - 2026-10-29 - Journal Article

An Evaluation of Precision in Implant Placement During the Early Learning Curve for the Direct Anterior Approach in Total Hip Arthroplasty.

Wilke BK, Choudhury P, Baranek ME, Garner HW, Iturregui J, Stanborough RO, Sebro RA

retrospective cohortLOE IIIn = 618 (5 surgeons, 1:1 matched DA vs prior approach cases)N/A

Topics

arthroplasty
PMID: 42954490DOI: 10.5435/JAAOS-D-24-00978View on PubMed ->

Key Takeaway

During the early DA approach learning curve, surgeons achieved superior precision in leg length restoration (p=0.003 vs PA; p=0.016 vs AL) and femoral offset (p=0.009 vs PA) compared to their prior approach, with no loss of acetabular inclination precision.

Summary Depth

Choose how much analysis to show on this article page.

Summary

Five surgeons transitioning from posterior or anterolateral to direct anterior approach THA had their early DA cases matched 1:1 with prior-approach cases; radiographic precision was compared using Bartlett test and F-test for variance homogeneity. DA approach yielded statistically superior precision for leg length vs both PA (p=0.003) and AL (p=0.016) approaches, and for femoral offset vs PA (p=0.009). Acetabular inclination precision was equivalent across all approach comparisons.

Key Limitation

The study measures radiographic precision as a surrogate for surgical quality but does not report complication rates, dislocation, or functional outcomes for the matched cohorts, leaving the clinical consequence of any variance differences unquantified.

Original Abstract

BACKGROUND

Acquiring new skills is associated with a requisite learning curve, with potential for increased complications. While previous studies have evaluated complications associated with the learning curve for the direct anterior approach, no studies have evaluated whether there is a decrease in surgical precision during this formative period. The purpose of our study was to compare the precision of implant placement during a surgeon's early learning curve with the direct anterior (DA) approach for total hip arthroplasty (THA) with that of the surgeon's previous approach.

METHODS

Between 7/2012 and 3/2021, five surgeons converted from a posterior (PA) or anterolateral (AL) approach to a DA approach for primary THA. For each surgeon, initial cases using the DA approach were compared 1:1 with cases using the PA or AL approach before the transition. Radiographic parameters were recorded for each patient. Statistical analysis was conducted using the Bartlett test (precision) for homogeneity of variances and the F-test for pairwise comparisons of variances across surgical approaches.

RESULTS

A total of 618 patients were included. Across all surgeons, the DA approach was more precise with postoperative leg length (P = 0.003) and femoral offset (P = 0.009) when compared with the PA approach and more precise with leg length (P = 0.016) when compared with the AL approach. No loss in precision was observed with the DA approach compared with the PA and AL approaches for acetabular inclination (all P < 0.05).

CONCLUSION

The direct anterior approach demonstrated comparable or improved precision with implant positioning even during a surgeon's early learning curve.