JOA - 2026-11-01 - Journal Article
Total Knee Arthroplasty Using Robotic-Assisted Technology in Patients Who Have Prior Anterior Cruciate Ligament Reconstruction.
Roman ER, Likine EF, Altman KM, Ayres CT, Richards JA, Smith NS, Mont MA, Malkani AL
Topics
Key Takeaway
RA-TKA in patients with prior ACLR achieved 96% all-cause survivorship at 2 years, statistically equivalent to 94% in matched controls without prior ACLR (P=0.604).
Summary Depth
Choose how much analysis to show on this article page.
Summary
This study asked whether RA-TKA could mitigate the historically elevated failure risk in patients with prior ACLR by using real-time intraoperative gap balancing data. 62 prior-ACLR patients from a consecutive RA-TKA series were matched 1:3 by sex, implant type, BMI, and age to controls; 53 ACLR patients completed minimum 2-year follow-up. No significant differences were found in ROM, PROMs, complications, or all-cause survivorship (96% vs. 94%, P=0.604).
Key Limitation
The 2-year follow-up is too short to detect the instability-driven failures that historically differentiate this population, making survivorship equivalence a preliminary rather than definitive finding.
Original Abstract
BACKGROUND
Total knee arthroplasty (TKA) in patients who have prior anterior cruciate ligament reconstruction (ACLR) has demonstrated decreased survivorship, with instability as the primary etiology of failure. Robotic-assisted TKA (RA-TKA) provides intraoperative gap data to help achieve a balanced soft-tissue sleeve. The purpose of this study was to evaluate outcomes, patient-reported outcome measures (PROMs), complications, and revisions in patients undergoing primary RA-TKA who had a history of prior ACLR.
METHODS
A review of 1,932 consecutive RA-TKAs was performed with preoperative computed tomography scan data and functional alignment techniques. There were 62 patients identified who had prior ACLRs and were matched 1:3 to a control group who did not have prior ACLR by sex, implant type, body mass index, and age. In the ACLR group, seven patients (11.3%) were lost to follow-up, and two underwent revision surgery, leaving 53 patients who had a minimum 2-year follow-up. The mean age was 55 years (range, 28 to 69), the mean body mass index was 32.8 (range, 21.6 to 49.1), and 43.5% were women. Clinical outcomes, PROMs, complications, and revisions were reported.
RESULTS
There were no significant postoperative differences between the study group and the control group in length of follow-up, range of motion, or PROMs. There were no significant differences between either group regarding complications or all-cause survivorship at two years of follow-up (P = 0.604).
CONCLUSIONS
The use of RA-TKA provided real-time adjustments in implant positioning to achieve a balanced soft-tissue sleeve, resulting in 96% survivorship at two years for all-cause failure in patients who had a prior ACLR compared to 94% survivorship for the control group (P = 0.604). Additional work is needed to determine if results of RA-TKA in patients who had prior ACLR demonstrate improved results compared to a group who had prior ACLR undergoing TKA using manual instruments.