<- Back to digest

JOA - 2026-11-01 - Journal Article; Comparative Study

Silk Fibroin Mesh Significantly Reduces Skin Reactions Compared to Cyanoacrylate Adhesives in Total Joint Arthroplasty.

Paul BR, Van Schuyver PR, Braithwaite CL, Tarabichi S, Verhey JT, Christopher ZK, Spangehl MJ, Bingham JS

retrospective cohortLOE IIIn = 797 patients, 874 procedures (626 CM, 248 SFM)N/A if not reported.

Topics

arthroplasty
PMID: 41720318DOI: 10.1016/j.arth.2026.02.027View on PubMed ->

Key Takeaway

Silk fibroin mesh reduced MARSI incidence from 4.7% to 1.2% versus cyanoacrylate mesh in primary TJA, with cyanoacrylate use carrying an OR of 4.41 for skin injury on multivariable analysis.

Summary Depth

Choose how much analysis to show on this article page.

Summary

This study compared MARSI incidence between cyanoacrylate mesh (CM) and silk fibroin mesh (SFM) wound closure in primary THA and TKA via retrospective review of 874 procedures. SFM reduced overall MARSI from 4.7% to 1.2% (P=0.03); the effect was significant for TKA (13.4% vs 2.3%, P=0.01) but not THA (2.5% vs 0.63%, P=0.21). Multivariable regression identified CM use (OR 4.41), TKA procedure (OR 4.11), and obesity (OR 2.67) as independent MARSI predictors, with no difference in downstream wound complications between groups.

Key Limitation

Non-randomized allocation of dressing type introduces confounding by indication, as surgeon or institutional preference—not patient characteristics—likely drove dressing selection, potentially biasing MARSI rates between groups.

Original Abstract

BACKGROUND

Medical adhesive-related skin injuries (MARSI) are common complications associated with traditional cyanoacrylate-based adhesives, leading to a range of adverse patient outcomes. Silk fibroin mesh (SFM) has emerged as a biocompatible alternative, designed to minimize these reactions while maintaining effective wound support; however, comparative data assessing its effectiveness in reducing wound complications remain limited. This study compared the incidence of MARSI, particularly allergic contact dermatitis, between cyanoacrylate mesh (CM) and SFM wound closure systems in total joint arthroplasty.

METHODS

All primary total hip (THA) and knee arthroplasty (TKA) cases at our institution that utilized CM or SFM wound closure were retrospectively reviewed. Revision arthroplasty, hemiarthroplasty, unicompartmental knee arthroplasty, and fracture fixation were excluded. The final cohort included 797 patients and 874 arthroplasty procedures, of which 626 utilized CM and 248 utilized SFM. Demographic characteristics, MARSI incidence, treatment patterns, and wound outcomes were collected and analyzed.

RESULTS

The incidence of MARSI was significantly higher with CM than SFM (4.7 versus 1.2%, P = 0.03). When stratified by procedure, MARSI occurred more frequently following TKA than THA for both dressing types (TKA: 13.4 CM versus 2.3% SFM, P = 0.01;

THA

2.5 CM versus 0.63% SFM, P = 0.21). On multivariable logistic regression, CM use (odds ratio (OR) 4.41 [1.45 to 19.2], P = 0.020), TKA procedure (OR 4.11 [1.81 to 9.34], P < 0.001), and obesity (OR 2.67 [1.17 to 6.52], P = 0.023) were independently associated with MARSI. There were no differences observed in MARSI management or wound-related complications between groups.

CONCLUSIONS

Silk fibroin mesh (SFM) is a promising wound dressing alternative to traditional CM, offering a lower risk of medical adhesive-related skin injury.

LEVEL OF EVIDENCE

III, retrospective cohort study.