<- Back to digest

BJJ - 2026-11-01 - Journal Article

Periprosthetic femoral fracture following primary hip arthroplasty : should the choice of femoral component design and fixation method vary according to the sex and age of the patient?

Børsheim S, Kristensen TB, Hallan G, Gjertsen JE, Furnes O, Dybvik E, Lie SA, Dale H

retrospective cohortLOE IIIn = 204,041Up to 20 years (2005–2025); exact mean not reported.

Topics

trauma
PMID: 42966374DOI: 10.1302/0301-620X.108B11.BJJ-2026-0178.R1View on PubMed ->

Key Takeaway

Polished taper-slip and uncemented collarless stems carry a nine-times higher reoperation risk for periprosthetic femoral fracture versus cemented composite beam stems in males across all ages.

Summary Depth

Choose how much analysis to show on this article page.

Summary

Using Cox regression on 204,041 primary hip arthroplasties from two Norwegian national registries, this study compared reoperation risk for periprosthetic femoral fracture across four femoral component categories stratified by sex and age. In males, polished taper-slip and uncemented collarless stems conferred a nine-times higher risk versus cemented composite beam (aHRR ~9.0), while uncemented collared stems carried a four-times higher risk. Age thresholds for elevated risk differed by sex and stem type, with cemented composite beam demonstrating the lowest risk across all subgroups.

Key Limitation

Absence of bone mineral density or canal morphology data prevents adjustment for the most clinically relevant confounder driving both implant selection and periprosthetic fracture susceptibility.

Original Abstract

AIMS

Periprosthetic femoral fracture is a severe complication following hip arthroplasty, influenced by the design of the femoral component and the method of fixation. The aim of this study was to investigate the influence of sex and age on the risk of reoperation for periprosthetic femoral fracture.

METHODS

We analyzed 204,041 primary hip arthroplasties from the Norwegian Arthroplasty Register and the Norwegian Hip Fracture Register (1 January 2005 to 31 December 2025). Femoral components were categorized as cemented composite beam (CB), cemented polished taper-slip (PTS), uncemented collarless (UCC-), and uncemented collared (UCC+). Cox regression analysis was used to compare the risk (adjusted hazard rate ratio (aHRR)) of reoperation for periprosthetic femoral fracture stratified by sex and age.

RESULTS

In males, PTS and UCC- had a nine-times higher risk of reoperation for periprosthetic femoral fracture than CB. For UCC+, the risk was four times higher than CB. The risk of reoperation for periprosthetic femoral fracture was increased in males aged > 65 years for UCC-; for UCC+ the risk was increased in males aged > 75 years, whereas PTS had higher risk for periprosthetic femoral fracture at all ages, compared with CB. In females, the risk of reoperation for periprosthetic femoral fracture was increased in those aged > 70 years for PTS and UCC+ compared with CB, whereas for UCC- the risk of periprosthetic femoral fracture was higher in those aged > 60 years, compared with CB.

CONCLUSION

Our findings suggest that CB should be the preferred choice of femoral component, at least for males aged > 75 years and females aged > 70 years. UCC+ components were the best uncemented option, while the use of PTS components was associated with a high risk of periprosthetic femoral fracture among males of all ages.