JBJS - 2026-11-04 - Journal Article
Impact of Stem Design on Periprosthetic Femoral Fracture Risk: Findings from 182,118 Primary Total Hip Arthroplasties in the Swiss National Joint Registry.
Bouché PA, Lübbeke A, Brand C, Gonzalez AI, Beck M, Hannouche D
Topics
Key Takeaway
In 182,118 primary THAs, cementless anatomic (type-7) stems carried an 88% higher PFF risk (HR=1.88) versus cementless type-3 stems, while composite-beam cemented stems (HR=0.45) and collared stems (HR=0.26) were independently protective.
Summary Depth
Choose how much analysis to show on this article page.
Summary
Using the Swiss National Joint Registry (SIRIS), this study evaluated whether femoral stem design independently predicts PFF risk after primary THA via multivariable Cox regression controlling for age, sex, ASA class, BMI, prior ipsilateral surgery, bearing, and cup type. Among 182,118 THAs, 1,226 (0.7%) sustained a PFF; cementless anatomic (Kheir type-7) stems conferred HR=1.88 versus type-3 stems, composite-beam cemented stems were most protective (HR=0.45), and collared stems independently reduced risk (HR=0.26). Patient-level risk amplifiers included age ≥75 years (HR up to 1.86), ASA 3–5 (HR≈1.70–1.73), BMI <18.5 or ≥40 kg/m², prior ipsilateral surgery (HR=1.32), and dual-mobility cup use (HR=1.56).
Key Limitation
Registry data lack canal morphology metrics (Dorr classification, canal flare index, cortical index) and surgeon-controlled press-fit variables that are the primary mechanical determinants of PFF in cementless stems, preventing causal attribution of risk to stem design independent of bone quality and fit.
Original Abstract
BACKGROUND
Periprosthetic femoral fractures (PFFs) are an increasingly common indication for revision total hip arthroplasty (THA). While patient-related risk factors are well documented, the influence of femoral stem design on PFF risk remains poorly characterized. In this study using nationwide data, we assessed the association between stem design and PFF risk.
METHODS
We analyzed 182,118 primary THAs (performed from 2015 to 2023) from the Swiss National Joint Registry (SIRIS). Cementless stems were categorized according to the Kheir classification, and cemented stems were categorized as double-tapered polished, triple-tapered polished, composite-beam, or custom. A multivariable Cox regression model, including variables such as age, sex, American Society of Anesthesiologists (ASA) class, body mass index (BMI), surgical indication, prior ipsilateral hip surgery, stem design, collar, dual-mobility cup, bearing, and head size, was analyzed. Hazard ratios (HRs) with 95% confidence intervals (CIs) are reported.
RESULTS
Among 182,118 THAs (mean patient age, 68.9 ± 11.5 years; female sex in 53.1% of cases), 1,226 (0.7%) were complicated by PFF. The cumulative incidence of PFF reached 0.7% at 5 years and 1.3% at 10 years. Higher PFF risk was associated with an age of 75 to 84 years (HR = 1.68 [95% CI = 1.44 to 1.96]) and ≥85 years (HR = 1.86 [95% CI = 1.47 to 2.35]), ASA class of 3 to 5 (females, HR = 1.70; males, HR = 1.73), BMI of <18.5 kg/m 2 (HR = 1.61) or ≥40 kg/m 2 (HR = 1.64), prior ipsilateral hip surgery (HR = 1.32), and use of a dual-mobility cup (HR = 1.56). Elective procedures (HR = 0.36) and collared stems (HR = 0.26) were associated with a lower risk. Compared with cementless type-3 stems, cementless type-7 (anatomic) stems showed a higher risk of PFF (HR = 1.88), whereas cementless type-1B (HR = 0.62) and composite-beam cemented stems (HR = 0.45) were protective.
CONCLUSIONS
In this large nationwide registry study, femoral stem design independently influenced PFF risk after primary THA. Cementless anatomic stems increased the risk, whereas composite-beam cemented stems and the presence of a collar conferred a protective effect. These findings support personalized implant selection, particularly for older patients or those with frailty.
LEVEL OF EVIDENCE
Prognostic Level III . See Instructions for Authors for a complete description of levels of evidence.