<- Back to digest

JSES - 2026-11-05 - Journal Article

Anatomical Conoid Ligament Reconstruction Improves Posterior Stability in Neer Type IIB Distal Clavicle Fractures: A Cadaveric Biomechanical Study.

Kurata S, Inoue K, Tsujimura K, Imanaka A, Kawamura K, Sinthubua A, Mahakkanukrauh P

cadavericLOE Vn = 12 cadaver shouldersN/A

Topics

shoulder elbowtraumabasic science
PMID: 42988208DOI: 10.1016/j.jse.2026.10.031View on PubMed ->

Key Takeaway

Anatomical (posterior) drill-hole placement for suture button tape fixation in Neer type IIB distal clavicle fractures reduces posterior displacement by a mean of 1.8 mm compared to anterior placement under 70-N posterior loading.

Summary Depth

Choose how much analysis to show on this article page.

Summary

This cadaveric biomechanical study compared anatomical (conoid tubercle) versus anterior one-third clavicular drill-hole positioning for suture button tape fixation in a Neer type IIB distal clavicle fracture model, with intact conoid as control. Under 70-N posterior loading, the anatomical group demonstrated a median displacement rate of 16.5% versus 23.7% in the anterior group (adjusted P=.031), a mean within-specimen difference of 1.8 mm (95% CI 0.6–2.9 mm). Under superior loading, both reconstruction groups outperformed the intact conoid control, but no significant difference between anatomical and anterior groups was detected.

Key Limitation

The 1.8 mm mean reduction in posterior displacement has not been correlated with any clinical outcome threshold, leaving the functional significance of anatomical versus anterior placement unestablished.

Original Abstract

HYPOTHESIS

This biomechanical study aimed to compare suture button tape (SBT) fixation techniques using different clavicular drill-hole positions in a Neer type IIB distal clavicle fracture (DCF) model. We hypothesized that anatomical conoid ligament reconstruction would provide greater posterior stability than that provided by anterior reconstruction without compromising superior stability.

METHODS

A Neer type IIB DCF model was created using 12 fresh-frozen cadaver shoulders and tested using the following three groups: conoid group (intact conoid ligament); anatomical group (drill hole placed at the posterior aspect of the clavicle over the conoid tubercle); and anterior group (drill hole placed at the anterior one-third of the clavicular width). Reduction accuracy was assessed by measuring displacement rates (superior, anteroposterior, and combined) at the reduced positions. Mechanical stability was evaluated by applying 70-N superior and posterior loads to the proximal clavicle and measuring displacement relative to the reduced position. A statistical analysis using Friedman tests was performed; if the results were significant, then pairwise Wilcoxon signed-rank tests were subsequently performed. Bonferroni correction was applied across all 21 pairwise comparisons. An adjusted P < .05 was considered significant.

RESULTS

No significant pairwise differences in reduction accuracy were detected after Bonferroni correction. Under superior loading, the median displacement rates were 33.2%, 4.2%, and 12.6% in the conoid, anatomical, and anterior groups, respectively. The displacement rate in the anatomical group was lower than that in the conoid group (adjusted P = .021). No significant difference between the two reconstruction groups was detected. Under posterior loading, median displacement rates were 48.1%, 16.5%, and 23.7% in the conoid, anatomical, and anterior groups, respectively. The displacement rate in the anatomical group was lower than that in the conoid and anterior groups (adjusted P = .010 and .031, respectively). The mean within-specimen difference in posterior displacement between the anterior and anatomical groups was 1.8 mm (95% confidence interval, 0.6-2.9 mm).

CONCLUSION

Anatomical reconstruction using SBT provided greater resistance to posterior displacement than that provided by anterior reconstruction, with a mean within-specimen reduction in posterior displacement of 1.8 mm under a 70-N posterior load. No statistically significant difference in superior displacement was detected between the two reconstruction groups. The clinical relevance of the observed posterior displacement difference has not yet been established.

LEVEL OF EVIDENCE

Basic Science Study, Biomechanics.