<- Back to digest

JSES - 2026-11-03 - Journal Article

The Effect of EVOLVE Radial Head Arthroplasty Stem Tilt on Clinical Outcomes.

Tat J, Kheiran A, Grewal R, Athwal GS, Faber KJ, Drosdowech DS, King GJW

retrospective cohortLOE IIIn = 61 (10 tilt, 51 controls)Not explicitly reported as mean; subgroup analysis compared 6-week and 1-year radiographs.

Topics

shoulder elbowhandtrauma
PMID: 42977117DOI: 10.1016/j.jse.2026.10.014View on PubMed ->

Key Takeaway

Excessive EVOLVE radial head arthroplasty stem tilt (neck-shaft angle >1 SD above mean) was associated with significantly worse PREE, QuickDASH, and MEPI scores compared to controls, with lateral overhang distance as a moderate predictor of PREE (R²=0.14) and MEPI (R²=0.10).

Summary Depth

Choose how much analysis to show on this article page.

Summary

This retrospective study compared clinical outcomes between EVOLVE smooth-stem RHA patients with excessive stem tilt (neck-shaft angle >1 SD above mean, n=10) versus controls (n=51) following isolated radial head fracture. The tilt group had significantly worse PREE, QuickDASH, and MEPI scores (all p<0.01), greater lateral overhang, and higher implant lucency rates, though complication and revision rates did not differ. Lateral overhang distance was a moderate independent predictor of PREE (R²=0.14) and MEPI (R²=0.10), and excessive tilt developed at late rather than early follow-up.

Key Limitation

The tilt group of only 10 patients is underpowered to detect meaningful differences in complication and reoperation rates, and the SD-based tilt threshold is implant- and cohort-specific, limiting generalizability.

Original Abstract

INTRODUCTION

Radial head arthroplasty (RHA) mal-alignment can occur when there is excessive tilt of the radial head stem relative to the radial canal. The etiology, clinical significance and management for increased RHA tilt is poorly understood. Our primary objective was to compare clinical outcomes in patients with excessive radiographic RHA tilt to controls. A secondary objective was to determine the relationship between radiographic stem alignment measurements and clinical outcomes.

METHODS

We performed a retrospective chart review of patients who underwent a smooth stem RHA (EVOLVE, Wright Medical) between 1999 - 2021 for acute radial head fractures requiring isolated RHA. Patient demographics, clinical outcomes scores (PREE, QuickDASH, MEPI), range of motion, complications, reoperations, and radiographic measurements were compared between patients with excessive RHA tilt and controls. Radial head alignment was assessed using several parameters including radial neck-shaft angle, lateral overhang distance RHA implant, proximal radioulnar joint angle, radial neck length, radial neck width, radial neck cut angle, radial tuberosity width, and radiocapitellar line. Excessive RHA tilt was defined as patients with a high-neck shaft angle (greater than 1 Standard Deviation above the mean), while controls had a neck-shaft angle less than 1 Standard Deviation. Regression modelling was used to determine whether the radiographic alignment parameters correlate with of outcomes (PREE, QuickDASH, MEPI), complications and reoperations. A subgroup analysis compared radiographic tilt at 6 weeks and 1 year postoperatively.

RESULTS

Sixty-one patients were included in the study, 10 patients with mal-alignment of the RHA and 51 patients in the control group. There was no significant difference in patient characteristics between groups (age, gender, handedness, smoking, time to surgery, follow-up time) (p>0.01). The tilt group demonstrated greater neck-shaft angles, RHA lateral overhang, PRUJ angles, and implant lucency, with shorter radial neck lengths and lower radial neck cut angles (all p<0.01). Patients with excessive tilt had worse clinical outcomes, including higher PREE and QuickDASH scores and lower MEPI scores (all p<0.01). Multiple linear regression showed overhang distance as a moderate predictor for PREE (R 2 =0.14, F 1,54 =9.7, p=0.003) and MEPI scores (R 2 =0.10, F 1,53 =7.3, p=0.009). Excessive tilt was more commonly observed at late rather than early follow-up.

CONCLUSION

A cohort of patients with excessive RHA tilt cohort had worse overall clinical outcomes scores when compared to the control group, however they did not demonstrate higher rates of complications or revision surgery. In this patient cohort, excessive implant tilt developed late after surgery rather than in early follow-up.