<- Back to digest

JOA - 2026-11-12 - Journal Article

Effect of Prosthesis Selection on Gap Balancing in Robotic-Assisted Cruciate-Retaining and Posterior-Stabilized Total Knee Arthroplasty: A Prospective Randomized Controlled Trial.

Yang C, Zhu K, Dai H, Yang D, Zhang X, Chen D, Wang Q, Cheng M

RCTLOE In = 120 (CR n=60, PS n=60)Minimum 2 years

Topics

arthroplasty
PMID: 43020156DOI: 10.1016/j.arth.2026.11.018View on PubMed ->

Key Takeaway

In robotic-assisted TKA using functional alignment, CR and PS designs produce equivalent 2-year clinical outcomes, but PS produces a significantly larger lateral flexion gap (P=0.027) and requires less lateral posterior condyle resection (P=0.048).

Summary Depth

Choose how much analysis to show on this article page.

Summary

This RCT randomized 120 patients to CR or PS robotic-assisted TKA using functional alignment principles, comparing intraoperative gap measurements, bone resection, femoral rotation, and 2-year clinical and radiographic outcomes. PS RA-TKA produced a significantly larger lateral flexion gap and required less lateral posterior condyle resection than CR RA-TKA, while extension gaps were equivalent between groups. No significant differences in pre- or postoperative clinical scores were observed between groups at 2-year follow-up.

Key Limitation

The study does not report PCL integrity assessment methodology or the rate of intraoperative conversion from CR to PS, making it impossible to determine how often the CR design was abandoned and whether the CR group represents a selected favorable anatomy.

Original Abstract

BACKGROUND

The study aimed to assess the disparities between robotic-assisted cruciate-retaining (CR) and posterior-stabilized (PS) total knee arthroplasty (RA-TKA) regarding flexion-extension gaps, bone resection amount, and postoperative knee function.

METHODS

Prospectively randomized into two groups, CR RA-TKA (n = 60) and PS RA-TKA (n = 60), 120 patients were scheduled for RA-TKA. All patients underwent RA-TKA to execute adjusted implant positioning, flexion-extension gaps, bone resection amount, femoral component rotation, and alignment by using a robotic-assisted system, following functional alignment principles, between September 1, 2021, and December 31, 2022. Patients underwent clinical and radiographic evaluations at the 2-year postoperative follow-up.

RESULTS

The extension gap results were similar between the two groups; the flexion gap was greater in the PS RA-TKA group, particularly on the lateral side (P = 0.027). Compared with the CR RA-TKA group, the PS RA-TKA group had significantly less bone resection of the lateral posterior condyle (P = 0.048). Although the PS group required less external rotation of the femoral component than the CR group, the difference was not statistically significant (P = 0.225). There were no significant differences in pre- or postoperative clinical scores between the two groups (P > 0.05).

CONCLUSION

The CR design demonstrated superior balance in terms of the flexion-extension gap numerical value compared to the PS design. While the PS RA-TKA group required less posterior femoral bone resection and less external rotation of the femoral component, no significant differences in clinical outcomes were observed between the groups at a minimum of two years postoperatively. For most patients who had varus deformity and an intact posterior cruciate ligament (PCL), the CR implant design remains a reliable option. However, for those who have major flexion gap imbalance or PCL deficiency, the PS design is recommended.