The Triple-Tapered Uncemented Femoral Stems in Slight Varus Demonstrated Excellent Early Survivorship and Clinical Results.
Kelley BE, Ji B, Bedard NA, Taunton MJ, Pagnano MW, Abdel MP, Hannon CP
Topics
Key Takeaway
Varus alignment occurred in 23.6% of triple-tapered uncemented stems and yielded 100% 5-year survivorship free of femoral revision versus 99.5% for neutral stems, with no statistically significant difference in revision, reoperation, or periprosthetic fracture rates.
Summary Depth
Choose how much analysis to show on this article page.
Summary
This study evaluated whether coronal stem alignment affects survivorship and complications in triple-tapered uncemented femoral stems across 1,730 primary THAs, classifying 76.0% as neutral, 23.6% as varus, and 0.4% as valgus at 3-month postoperative radiographs. All six femoral stem revisions (0.3%) occurred in neutrally aligned stems; 5-year survivorship free of femoral revision was 99.5% for neutral versus 100% for varus (P=0.60). Periprosthetic fracture rates trended lower in varus stems (0.2% vs. 1.1%, P=0.10), and collared versus collarless designs showed no significant difference in fracture incidence (P=0.18).
Key Limitation
Mean follow-up of 2 years is inadequate to assess whether varus alignment produces differential rates of aseptic loosening, stress shielding, or subsidence over the clinically relevant 10-year horizon.
Original Abstract
BACKGROUND
Femoral stem alignment in total hip arthroplasty (THA) can influence implant stability and long-term fixation. The triple-tapered uncemented stems have gained widespread use, and the recommended surgical technique often results in slight varus positioning. The effect of this alignment pattern on implant performance remains uncertain. The purpose of this study was to evaluate how coronal alignment of triple-tapered stems affects survivorship, periprosthetic fracture incidence, clinical outcomes, and radiographic results.
METHODS
A retrospective review of an institutional joint registry identified 1,730 primary THAs implanted with one of three triple-tapered, uncemented femoral stems. Coronal alignment at three months postoperatively classified 1,315 stems (76.0%) as neutral (0 ± 3°), 408 (23.6%) as varus, and seven (0.4%) as valgus. Outcomes assessed included revision and reoperation rates, periprosthetic fractures, Harris Hip Scores (HHS), and radiographic findings. The mean follow-up was two years (range, 2 to 8).
RESULTS
There were six femoral stem revisions (0.3%) that occurred, all in neutrally aligned stems, yielding a 5-year survivorship free of femoral revision of 99.5% (95% confidence interval [CI], 98.9 to 99.9) for neutral stems and 100% for varus stems (P = 0.60). Survivorship free of any revision (P = 0.82) or any reoperation (P = 0.68) did not differ between groups. Periprosthetic fractures occurred in 15 neutral stems (1.1%) and one varus stem (0.2%) (P = 0.10). Periprosthetic fracture rates were also similar between collared and collarless designs (P = 0.18).
CONCLUSIONS
More than 20% of triple-tapered stems were implanted in slight varus. Varus alignment did not adversely affect 5-year implant survivorship or periprosthetic fracture incidence. The triple-tapered uncemented stems, with or without a collar, demonstrated excellent early performance even when inserted in slight varus. These findings support the continued use of broach-based techniques that may naturally position the femoral stem in mild varus and provide reassurance that such alignment does not compromise early fixation or stability.