<- Back to digest

Journal of Children's Orthopaedics - 2026-11-13 - Journal Article

Locking-compression plate (LCP) or angled blade plates (ABP) for femoral osteotomies in children with spastic cerebral palsy (CP) gross motor function classification system (GMFCS) III, IV, and V.

Zaldivar B, Ramirez-Schneider LC, Balcázar-Muñoz EI, Arango-Piedrahita N, Macallister-Diaz JN, Mafla-Gómez M, Garcia-Rueda MF

retrospective cohortLOE IIIn = 285Mean 23 months

Topics

pediatricstraumaarthroplasty
PMID: 43034326DOI: 10.1177/18632521261483415View on PubMed ->

Key Takeaway

LCP and ABP show comparable overall hardware complication rates (4.9% vs 3.6%) for femoral osteotomies in GMFCS III-V CP patients, but all distal femur complications—peri-implant fracture, implant failure, and nonunion—occurred exclusively with ABP.

Summary Depth

Choose how much analysis to show on this article page.

Summary

This study compared hardware-related complications and intraoperative variables between LCP and ABP for proximal and/or distal femoral osteotomies in GMFCS III-V spastic CP patients under 18 years from 2015–2022. Generalized linear mixed-effects models were used to account for multiple procedures per patient. Overall complication rates were not significantly different (LCP 4.9%, ABP 3.6%), but all distal femur-specific complications occurred in the ABP group; LCP was associated with longer operative time and greater blood loss.

Key Limitation

The study is underpowered to detect statistically significant differences at the distal femur specifically, as proximal and distal osteotomy subgroups were not analyzed separately with adequate sample sizes.

Original Abstract

PURPOSE

To compare hardware-related complications and intraoperative variables between locking compression plates (LCP) and angled blade plates (ABP) used for proximal and/or distal femoral osteotomies in patients with spastic cerebral palsy (CP) classified as Gross Motor Function Classification System (GMFCS) III-V.

METHODS

A retrospective cohort study was conducted, including patients younger than 18 years with spastic CP (GMFCS III-V) who underwent proximal and/or distal femoral osteotomies between 2015 and 2022. Demographic variables, plate type, operative time, blood loss, and hardware-related complications (implant failure, peri-implant fracture, and non-union) were recorded. Comparisons between groups were performed using generalized linear mixed-effects models to account for patients with multiple procedures.

RESULTS

A total of 285 patients were included, with a mean follow-up of 23 months. Twenty-six complications occurred in 24 patients: 12 in the LCP group (4.9%) and 14 in the ABP group (3.6%). No significant differences were observed in overall complication rates between plate types for femoral osteotomies. All peri-implant fractures, implant failures, and non-unions at the distal femur were with ABP. LCP fixation was associated with longer operative time and greater blood loss.

CONCLUSIONS

LCP and ABP demonstrate comparable hardware-related complication rates in children with CP undergoing femoral osteotomies. Recommendations on hardware selection for distal femoral osteotomy warrant larger studies in non-ambulatory patients.

SIGNIFICANCE OF FINDINGS

Proximal femoral osteotomies in patients with CP can be performed with either hardware, with comparable complication rates; however, the focus of future studies should be on plate types for the distal femur.